Severe hemolysis caused by graft-derived anti-B production after lung transplantation

E Taaning, N Morling, S A Mortensen, G Pettersson, A C Simonsen

13 Citations (Scopus)

Abstract

Anti-B antibody causing sever hemolytic anemia and renal failure was found in the serum of a blood group B patient who had received a bilateral lung transplant from a blood group O donor. Although the donor origin of the antibody was not confirmed, it is likely that the anti-B antibody was produced by donor passenger B lymphocytes.
Original languageEnglish
JournalJournal of Heart and Lung Transplantation
Volume15
Issue number8
Pages (from-to)850-1
Number of pages1
ISSN1053-2498
Publication statusPublished - 1996