Decreased Leakage Rate of Colonic Anastomoses by Tachosil Coating: An Experimental Study

Hans-Christian Pommergaard, Michael Patrick Achiam, Jakob Burcharth, Jacob Rosenberg

3 Citations (Scopus)

Abstract

Colorectal anastomotic coating has been proposed as a means to lower the leakage rate. Prior to clinical testing, coating materials need thorough experimental evaluation to ensure safety and efficacy. The aim of this study was to evaluate Tachosil as an anastomotic coating agent. Technically insufficient colon anastomoses were created in 80 C57BL/6 mice, and in half of the animals the anastomoses were covered with Tachosil. The animals were examined for clinical signs of anastomotic leakage, and the breaking strength of the anastomoses was evaluated. The number of leakages was reduced by Tachosil coating (10/40 versus 20/40 in controls; P=0.037). However, more cases of large bowel obstruction were found in the Tachosil group (12/40 versus 0/40 in controls; P<0.0005). Breaking strength was comparable between the Tachosil and control groups (0.49 N versus 0.52 N, respectively; P=0.423). Clinical studies are needed to clarify the efficacy of Tachosil anastomotic coating.

Original languageEnglish
JournalInternational Surgery
Volume99
Issue number4
Pages (from-to)359-363
Number of pages5
ISSN0020-8868
DOIs
Publication statusPublished - 25 Jul 2014

Fingerprint

Dive into the research topics of 'Decreased Leakage Rate of Colonic Anastomoses by Tachosil Coating: An Experimental Study'. Together they form a unique fingerprint.

Cite this