Abstract
Here, we demonstrate that punches from buccal swab samples preserved on FTA cards can be used for high-throughput DNA sequencing, also known as massively parallel sequencing (MPS). We typed 44 reference samples with the HID-Ion AmpliSeq Identity Panel using washed 1.2 mm punches from FTA cards with buccal swabs and compared the results with those obtained with DNA extracted using the EZ1 DNA Investigator Kit. Concordant profiles were obtained for all samples. Our protocol includes simple punch, wash, and PCR steps, reducing cost and hands-on time in the laboratory. Furthermore, it facilitates automation of DNA sequencing.
Originalsprog | Engelsk |
---|---|
Tidsskrift | BioTechniques |
Vol/bind | 61 |
Udgave nummer | 3 |
Sider (fra-til) | 149-151 |
Antal sider | 3 |
ISSN | 0736-6205 |
DOI | |
Status | Udgivet - sep. 2016 |