Direct coupling of electromembrane extraction to mass spectrometry: Advancing the probe functionality toward measurements of zwitterionic drug metabolites

    7 Citationer (Scopus)

    Abstract

    A triple-flow electromembrane extraction (EME) probe was developed and coupled directly to electrospray-ionization mass spectrometry (ESI-MS). Metabolic reaction mixtures (pH 7.4) containing drug substances and related metabolites were continuously drawn (20 μL/min) into the EME probe in one flow channel, and mixed inside the probe with 7.5 μL min-1 of 1 M formic acid as make-up flow from a second flow channel. Following this acidification, the drug substances and their related metabolites were continuously extracted by EME at 400 V, across a supported liquid membrane (SLM) comprising 2-nitrophenyl octyl ether (and for some experiments containing 30% triphenyl phosphate (TPP)), and into 20 μL min-1 of formic acid as acceptor phase, which was introduced through a third flow channel. The acceptor phase was pumped directly to the MS system, and the ion intensity of extracted analytes was followed continuously as function of time. The triple-flow EME probe was used for co-extraction of positively charged parent drugs and their zwitterionic drug metabolites (hydroxyzine and its carboxylic acid metabolite cetirizine; and vortioxetine and its carboxylic acid metabolite Lu AA34443). While the zwitterionic metabolites could not be extracted at pH 7.4, it was shown that by acidifying the sample solution the zwitterionic metabolites could be extracted effectively. Various extraction parameters like make-up flow, extraction voltage and SLM composition were optimized for simultaneous extraction of parent drugs and metabolites. It was found that TPP added to the SLM improved extraction efficiencies of certain drug metabolites. Finally the optimized and characterized triple-flow EME probe was used for online studying the in-vitro metabolism of hydroxyzine and vortioxetine by rat liver microsomes. Due to the automated pre-extraction acidification of the rat liver microsomal solutions, it was possible to continuously monitor formation of the zwitterionic drug metabolites. As the triple-flow EME probe allowed modification of the pH of the sample without changing the pH in the bulk sample, the system can potentially be used for direct analysis of various kinds of chemical reactions that have to be run at pH conditions unfavorable for direct analyte extractions.
    OriginalsprogEngelsk
    TidsskriftAnalytica Chimica Acta
    Vol/bind983
    Sider (fra-til)121-129
    Antal sider9
    ISSN0003-2670
    DOI
    StatusUdgivet - 29 aug. 2017

    Fingeraftryk

    Dyk ned i forskningsemnerne om 'Direct coupling of electromembrane extraction to mass spectrometry: Advancing the probe functionality toward measurements of zwitterionic drug metabolites'. Sammen danner de et unikt fingeraftryk.

    Citationsformater