TY - JOUR
T1 - Validation of five minimally obstructive methods to estimate physical activity energy expenditure in young adults in semi-standardized settings
AU - Schneller, Mikkel Bo
AU - Pedersen, Mogens Theisen
AU - Gupta, Nidhi
AU - Aadahl, Mette
AU - Holtermann, Andreas
N1 - CURIS 2015 NEXS 108
PY - 2015/3/12
Y1 - 2015/3/12
N2 - We compared the accuracy of five objective methods, including two newly developed methods combining accelerometry and activity type recognition (Acti4), against indirect calorimetry, to estimate total energy expenditure (EE) of different activities in semi-standardized settings. Fourteen participants performed a standardized and semi-standardized protocol including seven daily life activity types, while having their EE measured by indirect calorimetry. Simultaneously, physical activity was quantified by an ActivPAL3, two ActiGraph GT3X+'s and an Actiheart. EE was estimated by the standard ActivPAL3 software (ActivPAL), ActiGraph GT3X+ (ActiGraph) and Actiheart (Actiheart), and by a combination of activity type recognition via Acti4 software and activity counts per minute (CPM) of either a hip- or thigh-worn ActiGraph GT3X+ (AGhip + Acti4 and AGthigh + Acti4). At group level, estimated physical activities EE by Actiheart (MSE = 2.05) and AGthigh + Acti4 (MSE = 0.25) were not significantly different from measured EE by indirect calorimetry, while significantly underestimated by ActiGraph, ActivPAL and AGhip + Acti4. AGthigh + Acti4 and Actiheart explained 77% and 45%, of the individual variations in measured physical activity EE by indirect calorimetry, respectively. This study concludes that combining accelerometer data from a thigh-worn ActiGraph GT3X+ with activity type recognition improved the accuracy of activity specific EE estimation against indirect calorimetry in semi-standardized settings compared to previously validated methods using CPM only.
AB - We compared the accuracy of five objective methods, including two newly developed methods combining accelerometry and activity type recognition (Acti4), against indirect calorimetry, to estimate total energy expenditure (EE) of different activities in semi-standardized settings. Fourteen participants performed a standardized and semi-standardized protocol including seven daily life activity types, while having their EE measured by indirect calorimetry. Simultaneously, physical activity was quantified by an ActivPAL3, two ActiGraph GT3X+'s and an Actiheart. EE was estimated by the standard ActivPAL3 software (ActivPAL), ActiGraph GT3X+ (ActiGraph) and Actiheart (Actiheart), and by a combination of activity type recognition via Acti4 software and activity counts per minute (CPM) of either a hip- or thigh-worn ActiGraph GT3X+ (AGhip + Acti4 and AGthigh + Acti4). At group level, estimated physical activities EE by Actiheart (MSE = 2.05) and AGthigh + Acti4 (MSE = 0.25) were not significantly different from measured EE by indirect calorimetry, while significantly underestimated by ActiGraph, ActivPAL and AGhip + Acti4. AGthigh + Acti4 and Actiheart explained 77% and 45%, of the individual variations in measured physical activity EE by indirect calorimetry, respectively. This study concludes that combining accelerometer data from a thigh-worn ActiGraph GT3X+ with activity type recognition improved the accuracy of activity specific EE estimation against indirect calorimetry in semi-standardized settings compared to previously validated methods using CPM only.
U2 - 10.3390/s150306133
DO - 10.3390/s150306133
M3 - Journal article
C2 - 25781506
SN - 1424-8220
VL - 15
SP - 6133
EP - 6151
JO - Sensors
JF - Sensors
IS - 3
ER -