TY - JOUR
T1 - Timed up & go test score in patients with hip fracture is related to the type of walking aid
AU - Kristensen, Morten T
AU - Bandholm, Thomas
AU - Holm, Bente
AU - Ekdahl, Charlotte
AU - Kehlet, Henrik
N1 - Keywords: Adult; Aged; Aged, 80 and over; Crutches; Female; Hip Fractures; Hospitals, University; Humans; Male; Middle Aged; Mobility Limitation; Physical Therapy Modalities; Prospective Studies; Walkers; Walking
PY - 2009
Y1 - 2009
N2 - Kristensen MT, Bandholm T, Holm B, Ekdahl C, Kehlet H. Timed Up & Go test score in patients with hip fracture is related to the type of walking aid. OBJECTIVE: To determine the relationship between Timed Up & Go (TUG) test scores and type of walking aid used during the test, and to determine the feasibility of using the rollator as a standardized walking aid during the TUG in patients with hip fracture who were allowed full weight-bearing (FWB). DESIGN: Prospective methodological study. SETTING: An acute orthopedic hip fracture unit at a university hospital. PARTICIPANTS: Patients (N=126; 90 women, 36 men) with hip fracture with a mean age +/- SD of 74.8+/-12.7 years performed the TUG the day before discharge from the orthopedic ward. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: The TUG was performed with the walking aid the patient was to be discharged with: a walker (n=88) or elbow crutches (n=38). In addition, all patients also performed the TUG using a rollator. RESULTS: Patients who performed the TUG with a walker were on average 13.6 (95% confidence interval [CI], 11.2-16.1) seconds faster using a rollator compared with the walker (P<.001). Correspondingly, patients who performed the TUG with crutches were on average 3.5 (95% CI, 1.5-5.4) seconds faster using a rollator compared with elbow crutches (P=.001). In both patient groups, the between walking-aid scores were strongly correlated (r>.833, P<.001). CONCLUSIONS: TUG scores are significantly related to the type of walking aid used during the test in patients with hip fracture who are allowed FWB when discharged from the hospital, but all patients were able to perform the TUG using the rollator as a standardized walking aid. Our findings indicate the importance of using a standardized walking aid when evaluating changes or comparing TUG scores in patients with hip fracture.
AB - Kristensen MT, Bandholm T, Holm B, Ekdahl C, Kehlet H. Timed Up & Go test score in patients with hip fracture is related to the type of walking aid. OBJECTIVE: To determine the relationship between Timed Up & Go (TUG) test scores and type of walking aid used during the test, and to determine the feasibility of using the rollator as a standardized walking aid during the TUG in patients with hip fracture who were allowed full weight-bearing (FWB). DESIGN: Prospective methodological study. SETTING: An acute orthopedic hip fracture unit at a university hospital. PARTICIPANTS: Patients (N=126; 90 women, 36 men) with hip fracture with a mean age +/- SD of 74.8+/-12.7 years performed the TUG the day before discharge from the orthopedic ward. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: The TUG was performed with the walking aid the patient was to be discharged with: a walker (n=88) or elbow crutches (n=38). In addition, all patients also performed the TUG using a rollator. RESULTS: Patients who performed the TUG with a walker were on average 13.6 (95% confidence interval [CI], 11.2-16.1) seconds faster using a rollator compared with the walker (P<.001). Correspondingly, patients who performed the TUG with crutches were on average 3.5 (95% CI, 1.5-5.4) seconds faster using a rollator compared with elbow crutches (P=.001). In both patient groups, the between walking-aid scores were strongly correlated (r>.833, P<.001). CONCLUSIONS: TUG scores are significantly related to the type of walking aid used during the test in patients with hip fracture who are allowed FWB when discharged from the hospital, but all patients were able to perform the TUG using the rollator as a standardized walking aid. Our findings indicate the importance of using a standardized walking aid when evaluating changes or comparing TUG scores in patients with hip fracture.
U2 - 10.1016/j.apmr.2009.05.013
DO - 10.1016/j.apmr.2009.05.013
M3 - Journal article
C2 - 19801068
SN - 0003-9993
VL - 90
SP - 1760
EP - 1765
JO - Archives of Physical Medicine and Rehabilitation
JF - Archives of Physical Medicine and Rehabilitation
IS - 10
ER -