Selective flow injection analysis of ultra-trace amounts of Cr(VI), preconcentration of it by solvent extraction, and determination by electrothermal atomic absorption spectrometry (ETAAS)

Steffen Chen Nielsen, Stefan Stürup, Henrik Spliid, Elo Harald Hansen*

*Corresponding author for this work
    57 Citations (Scopus)

    Abstract

    A rapid, robust, sensitive and selective time-based flow injection (FI) on-line solvent extraction system interfaced with electrothermal atomic absorption spectrometry (ETAAS) is described for analyzing ultra-trace amounts of Cr(VI). The sample is initially mixed on-line with isobutyl methyl ketone (IBMK). The Cr(VI) is complexed by reaction with ammonium pyrrolidine dithiocarbamate (APDC), and the non-charged Cr(VI)-PDC chelate formed is extracted into IBMK in a knotted reactor made from PTFE tubing. The organic extractant is separated from the aqueous phase by a gravity phase separator with a small conical cavity and delivered into a collector tube, from which 55 μl organic concentrate is subsequently introduced via an air flow into the graphite tube of the ETAAS instrument. The operations of the FI-system and the ETAAS detector are synchronously coupled. A significant advantage of the approach is that matrix constituents, such as high salt contents, effectively are eliminated. The extraction procedure was optimized by a simplex approach. A central composite design was subsequently employed to verify the estimated operational optimum. An 18-fold enhancement in sensitivity of Cr(VI) was achieved after preconcentration for 99 s at a sample flow rate of 5.5 ml min-1, as compared to direct introduction of 55 μl of sample, yielding a detection limit (3σ) of 3.3 ng l-1. The sampling frequency was 24.2 samples h-1. The proposed method was successfully evaluated by analyzing a NIST Cr(VI)-reference material, synthetic seawater and waste waters, and waste water samples from an incineration plant and a desulphurization plant, respectively.

    Original languageEnglish
    JournalTalanta
    Volume49
    Issue number5
    Pages (from-to)1027-1044
    Number of pages18
    ISSN0039-9140
    DOIs
    Publication statusPublished - 1 Aug 1999

    Keywords

    • Assay of inorganic Cr(VI)
    • Extraction of Cr(VI)-PDC complex
    • FI- ETAAS
    • On-line preconcentration of Cr(VI)

    Fingerprint

    Dive into the research topics of 'Selective flow injection analysis of ultra-trace amounts of Cr(VI), preconcentration of it by solvent extraction, and determination by electrothermal atomic absorption spectrometry (ETAAS)'. Together they form a unique fingerprint.

    Cite this