Resting and exercise haemodynamics in relation to six-minute walk test in patients with heart failure and preserved ejection fraction

Emil Wolsk, David Kaye, Barry A. Borlaug, Daniel Burkhoff, Dalane W. Kitzman, Jan Komtebedde, Carolyn S.P. Lam, Piotr Ponikowski, Sanjiv J. Shah, Finn Gustafsson*

*Corresponding author for this work
23 Citations (Scopus)

Abstract

Aims: Patients with heart failure and preserved ejection fraction (HFpEF) are characterized by functional impairment and an abnormal haemodynamic response to exercise. The six-minute walk test (6MWT) serves as a standardized test for functional capacity quantification in heart failure patients, and is associated with cardiovascular outcomes. However, as the association between 6MWT and haemodynamic parameters during rest and exercise in HFpEF patients is unknown, we sought to elucidate this relationship. Methods and results: Overall, 64 patients enrolled in the REDUCE LAP-HF trial completed a 6MWT at baseline. Univariate and multivariable linear regression models were used to assess the associations between 6MWT and measured or derived haemodynamic variables at baseline, during light/moderate exercise (20 W), and at peak supine exercise. The average 6MWT distance was 318 ± 106 m. At rest, in a multivariable model, only pulmonary capillary wedge pressure (PCWP) was significantly associated with 6MWT [coefficient: –5.4, 95% confidence interval (CI) –10.4, –0.5, P = 0.033]. During light/moderate exercise, mean pulmonary artery pressure was associated with 6MWT in a multivariable model (coefficient: –3.5, 95% CI –6.8, –0.3, P = 0.033). During peak exercise, central venous pressure, cardiac index (CI), and PCWP/CI correlated with 6MWT; however, workload corrected PCWP was the only variable independently associated with 6MWT (coefficient: –0.8, 95% CI –1.3, –0.4, P < 0.001). The variance in 6MWT was modestly explained by measured or derived haemodynamic variables at rest or at any stage of exercise (r2 = 7–17%). Conclusion: Workload corrected PCWP correlated best with 6MWT performance in HFpEF patients. Baseline haemodynamic variables were modestly correlated with 6MWT, suggesting that 6MWT performance in HFpEF patients may be significantly influenced by extra-cardiac factors.

Original languageEnglish
JournalEuropean Journal of Heart Failure
Volume20
Issue number4
Pages (from-to)715-722
Number of pages8
ISSN1388-9842
DOIs
Publication statusPublished - 2018

Keywords

  • Exercise
  • Haemodynamics
  • Heart failure with preserved ejection fraction
  • REDUCE LAP-HF
  • Six-minute walk test

Fingerprint

Dive into the research topics of 'Resting and exercise haemodynamics in relation to six-minute walk test in patients with heart failure and preserved ejection fraction'. Together they form a unique fingerprint.

Cite this