Reliability of knee joint range of motion and circumference measurements after total knee arthroplasty: does tester experience matter?

Thomas Linding Jakobsen, Malene Christensen, Stine Sommer Christensen, Marie Olsen, Thomas Bandholm

    78 Citations (Scopus)

    Abstract

    Background and Purpose: Two of the most utilized outcome measures to assess knee joint range of motion (ROM) and intra-articular effusion are goniometry and circumference, respectively. Neither goniometry nor circumference of the knee joint have been examined for both intra-tester and inter-tester in patients with total knee arthroplasty (TKA). The purpose of this study was to determine the intra-tester and inter-tester reliability of active and passive knee joint ROM and circumference in patients with TKA when administered by physiotherapists (testers) with different clinical experience. Method: The design was an intra-tester, inter-tester and intra-day reliability study. Nineteen outpatients (10 females) having received a TKA were examined by an inexperienced and an experienced physiotherapist. Following a standardized protocol, active and passive knee joint ROM and circumference measurements were obtained using a universal goniometer and a tape measure, respectively. To establish reliability, intraclass correlation coefficients (ICC2,1) and smallest real difference (SRD) were calculated. Results: The knee joint ROM and circumference measurements were generally reliable (ICC > 0.8) within and between physiotherapists (except passive knee extension). Changes in knee joint ROM of more than 6.6° and 10° (except active knee flexion) and knee joint circumference of more than 1.0cm and 1.63cm represent a real clinical improvement (SRD) or deterioration for a single individual within and between physiotherapists, respectively. Generally, the experienced tester recorded larger knee joint ROM and lower circumference values than that of the inexperienced tester. Conclusions: In clinical practice, we suggest that repeated knee goniometric and circumferential measurements should be recorded by the same physiotherapist in individual patients with TKA. Tester experience appears not to influence the degree of reliability.

    Original languageEnglish
    JournalPhysiotherapy research international : the journal for researchers and clinicians in physical therapy
    Volume15
    Issue number3
    Pages (from-to)126-34
    Number of pages8
    ISSN1358-2267
    DOIs
    Publication statusPublished - Sept 2010

    Fingerprint

    Dive into the research topics of 'Reliability of knee joint range of motion and circumference measurements after total knee arthroplasty: does tester experience matter?'. Together they form a unique fingerprint.

    Cite this