TY - JOUR
T1 - Randomized comparison of distal protection versus conventional treatment in primary percutaneous coronary intervention: the drug elution and distal protection in ST-elevation myocardial infarction (DEDICATION) trial
AU - Kelbaek, Henning
AU - Terkelsen, Christian J
AU - Helqvist, Steffen
AU - Lassen, Jens F
AU - Clemmensen, Peter
AU - Kløvgaard, Lene
AU - Kaltoft, Anne
AU - Engstrøm, Thomas
AU - Bøtker, Hans E
AU - Saunamäki, Kari
AU - Krusell, Lars R
AU - Jørgensen, Erik
AU - Hansen, Hans-Henrik T
AU - Christiansen, Evald H
AU - Ravkilde, Jan
AU - Køber, Lars
AU - Kofoed, Klaus F
AU - Thuesen, Leif
N1 - Keywords: Angioplasty, Transluminal, Percutaneous Coronary; Atherectomy, Coronary; Coronary Thrombosis; Drug-Eluting Stents; Electrocardiography; Female; Humans; Male; Middle Aged; Myocardial Infarction; Treatment Outcome
PY - 2008
Y1 - 2008
N2 - OBJECTIVES: The purpose of this study was to evaluate the use of distal protection during percutaneous coronary intervention (PCI) for ST-segment elevation myocardial infarction (STEMI) in native coronary vessels. BACKGROUND: Embolization of material from the infarct-related lesion during PCI may result in impaired myocardial perfusion and worsen the prognosis. Previous attempts to protect the microcirculation during primary PCI have had conflicting results. METHODS: We randomly assigned 626 patients with STEMI referred within 12 h to have PCI performed with (n = 312) or without (n = 314) distal protection. The primary end point was complete (>or=70%) ST-segment resolution detected by continuous ST-segment monitoring. Blood levels of troponin-T and creatine kinase-MB were monitored before and after the procedure, and echocardiographic determination of the left ventricular wall motion index (WMI) was performed before discharge. RESULTS: Patients were well matched in terms of demographic and angiographic baseline characteristics. There was no significant difference in the occurrence of the primary end point (76% vs. 72%, p = 0.29), no difference in maximum troponin-T (4.8 microg/l and 5.0 microg/l, p = 0.87) or maximum creatine kinase-MB (185 microg/l and 184 microg/l, p = 0.99), and no difference in median WMI (1.70 vs. 1.70, p = 0.35). The rate of major adverse cardiac and cerebral events (MACCE) 1 month after PCI was 5.4% with distal protection and 3.2% with conventional treatment (p = 0.17). CONCLUSIONS: The routine use of distal protection by a filterwire system during primary PCI does not seem to improve microvascular perfusion, limit infarct size, or reduce the occurrence of MACCE.
AB - OBJECTIVES: The purpose of this study was to evaluate the use of distal protection during percutaneous coronary intervention (PCI) for ST-segment elevation myocardial infarction (STEMI) in native coronary vessels. BACKGROUND: Embolization of material from the infarct-related lesion during PCI may result in impaired myocardial perfusion and worsen the prognosis. Previous attempts to protect the microcirculation during primary PCI have had conflicting results. METHODS: We randomly assigned 626 patients with STEMI referred within 12 h to have PCI performed with (n = 312) or without (n = 314) distal protection. The primary end point was complete (>or=70%) ST-segment resolution detected by continuous ST-segment monitoring. Blood levels of troponin-T and creatine kinase-MB were monitored before and after the procedure, and echocardiographic determination of the left ventricular wall motion index (WMI) was performed before discharge. RESULTS: Patients were well matched in terms of demographic and angiographic baseline characteristics. There was no significant difference in the occurrence of the primary end point (76% vs. 72%, p = 0.29), no difference in maximum troponin-T (4.8 microg/l and 5.0 microg/l, p = 0.87) or maximum creatine kinase-MB (185 microg/l and 184 microg/l, p = 0.99), and no difference in median WMI (1.70 vs. 1.70, p = 0.35). The rate of major adverse cardiac and cerebral events (MACCE) 1 month after PCI was 5.4% with distal protection and 3.2% with conventional treatment (p = 0.17). CONCLUSIONS: The routine use of distal protection by a filterwire system during primary PCI does not seem to improve microvascular perfusion, limit infarct size, or reduce the occurrence of MACCE.
U2 - 10.1016/j.jacc.2007.10.047
DO - 10.1016/j.jacc.2007.10.047
M3 - Journal article
C2 - 18308157
SN - 0735-1097
VL - 51
SP - 899
EP - 905
JO - Journal of the American College of Cardiology
JF - Journal of the American College of Cardiology
IS - 9
ER -