TY - JOUR
T1 - Particle formation and characteristics of Celecoxib-loaded poly(lactic-co-glycolic acid) microparticles prepared in different solvents using electrospraying
AU - Bohr , Adam
AU - Yang, Mingshi
AU - Baldursdottir, Stefania G.
AU - Kristensen , Jakob
AU - Dyas, Mark
AU - Stride , Eleanor
AU - Edirisinghe, Mohan
PY - 2012/7/6
Y1 - 2012/7/6
N2 - Microparticles were fabricated for pharmaceutical purposes using electrospraying with the aim to determine the effect of the solvent(s) used. Particles of poly(lactic-co-glycolic acid) (PLGA) and the drug Celecoxib were prepared from acetone, acetonitrile and acetone:methanol with different polymer and drug concentrations. The solvent power, evaporation rate and electrical conductivity of the solvents all had a significant effect on the particle formation process as well as the particle characteristics and drug release profile. Particles were near-spherical and between 2 and 7 μm in diameter with smooth or corrugated surfaces. The drug release rate was mainly dependent on particle size, with larger particles showing slower release. The solvent in which PLGA was poorly soluble resulted in small grainy particles that disintegrated instantaneously with full drug release. It may be concluded that the selection of an appropriate solvent may be a useful way to control particle characteristics and drug release profiles when using electrospraying.
AB - Microparticles were fabricated for pharmaceutical purposes using electrospraying with the aim to determine the effect of the solvent(s) used. Particles of poly(lactic-co-glycolic acid) (PLGA) and the drug Celecoxib were prepared from acetone, acetonitrile and acetone:methanol with different polymer and drug concentrations. The solvent power, evaporation rate and electrical conductivity of the solvents all had a significant effect on the particle formation process as well as the particle characteristics and drug release profile. Particles were near-spherical and between 2 and 7 μm in diameter with smooth or corrugated surfaces. The drug release rate was mainly dependent on particle size, with larger particles showing slower release. The solvent in which PLGA was poorly soluble resulted in small grainy particles that disintegrated instantaneously with full drug release. It may be concluded that the selection of an appropriate solvent may be a useful way to control particle characteristics and drug release profiles when using electrospraying.
U2 - 10.1016/j.polymer.2012.05.002
DO - 10.1016/j.polymer.2012.05.002
M3 - Journal article
SN - 0032-3861
VL - 53
SP - 3220
EP - 3229
JO - Polymer Communications (Guildford, England)
JF - Polymer Communications (Guildford, England)
IS - 15
ER -