N2 - A 350-kHz He plasma sustained on-column was evaluated for N-, O- and P-selective atomic emission detection in capillary gas chromatography. As the plasma caused peak tailing when sustained in 2.0 ml/min of carrier gas, 15 ml/min of auxiliary helium was added to the discharge. For N- and O-selective detection, CH4 mixed with O2 or N2, respectively, were used as plasma dopant. Even with this extensive plasma doping, non-specific responses arose from eluting hydrocarbons due to temporary changes in the background level of atomic N and O. Without background correction, element-to-carbon selectivities for N and O were limited to 100:1 and 40:1, respectively. For both elements, detection limits at the 50 pg/s level and linearities of 5 · 102 were obtained. P-selective detection was carried out with H2-CH4 as plasma dopant, and provided a 39 pg/s detection limit for P. The phosphorus-to-carbon selectivity was 2300:1 and the linearity was 2 · 102. With background correction, both selectivities and detection limits are expected to improve significantly.
AB - A 350-kHz He plasma sustained on-column was evaluated for N-, O- and P-selective atomic emission detection in capillary gas chromatography. As the plasma caused peak tailing when sustained in 2.0 ml/min of carrier gas, 15 ml/min of auxiliary helium was added to the discharge. For N- and O-selective detection, CH4 mixed with O2 or N2, respectively, were used as plasma dopant. Even with this extensive plasma doping, non-specific responses arose from eluting hydrocarbons due to temporary changes in the background level of atomic N and O. Without background correction, element-to-carbon selectivities for N and O were limited to 100:1 and 40:1, respectively. For both elements, detection limits at the 50 pg/s level and linearities of 5 · 102 were obtained. P-selective detection was carried out with H2-CH4 as plasma dopant, and provided a 39 pg/s detection limit for P. The phosphorus-to-carbon selectivity was 2300:1 and the linearity was 2 · 102. With background correction, both selectivities and detection limits are expected to improve significantly.
UR - http://www.scopus.com/inward/record.url?scp=0028587130&partnerID=8YFLogxK
U2 - 10.1016/0021-9673(94)00072-7
DO - 10.1016/0021-9673(94)00072-7
M3 - Journal article
AN - SCOPUS:0028587130
SN - 0301-4770
VL - 686
SP - 109
EP - 119
JO - Journal of Chromatography
JF - Journal of Chromatography
IS - 1
ER -