TY - JOUR
T1 - Investigation of the thrombin-generating capacity, evaluated by thrombogram, and clot formation evaluated by thrombelastography of platelets stored in the blood bank for up to 7 days
AU - Johansson, Per Ingemar
AU - Svendsen, M.S.
AU - Salado, J.
AU - Bochsen, L.
AU - Kristensen, Annemarie Thuri
PY - 2008
Y1 - 2008
N2 - BACKGROUND AND OBJECTIVES: Transfusion based on the Thrombelastograph (TEG) results reduces transfusion requirements in cardiac surgery and in liver transplantation. Taking the pivotal role of thrombin generation in the coagulation process into consideration, the clinical utility of the TEG may, in part, depend on its reflection of the dynamics of thrombin generation. MATERIAL AND METHODS: The kinetics of thrombin generation of platelets stored for 2 and 7 days, respectively, was assessed by calibrated automated thrombogram (CAT) and the lag time (min), time to peak (ttPeak; min), peak (nm thrombin) and endogenous thrombin potential (ETP; nm thrombin*min) were registered. Clot formation was evaluated by TEG and the R time (min), maxial amplitude (MA; mm), time to maximum thrombus generation (TMG; min) and maximum thrombus generation (MTG; dynes cm(-2) s(-1)) and total thrombus generation (TTG; dyne cm(-2)) were registered. RESULTS: Platelets become more procoagulant, evaluated both by TEG and CAT during storage. The reduction in CAT lag time and the ttPeak correlated with a decrease in the TEG R time and TMG (P < 0.0001) as did the CAT peak thrombin generation and the TEG MTG (P = 0.0035). No correlation between ETP and TTG was found (P = 0.65). CONCLUSION: The kinetics of thrombin generation, as evaluated by CAT, correlates with the thrombus generation, as evaluated by thrombelastography and this may in part explain the clinical utility of the TEG in identifying clinically relevant coagulopathies, secondary to impaired thrombin generation
Udgivelsesdato: 2008/2
AB - BACKGROUND AND OBJECTIVES: Transfusion based on the Thrombelastograph (TEG) results reduces transfusion requirements in cardiac surgery and in liver transplantation. Taking the pivotal role of thrombin generation in the coagulation process into consideration, the clinical utility of the TEG may, in part, depend on its reflection of the dynamics of thrombin generation. MATERIAL AND METHODS: The kinetics of thrombin generation of platelets stored for 2 and 7 days, respectively, was assessed by calibrated automated thrombogram (CAT) and the lag time (min), time to peak (ttPeak; min), peak (nm thrombin) and endogenous thrombin potential (ETP; nm thrombin*min) were registered. Clot formation was evaluated by TEG and the R time (min), maxial amplitude (MA; mm), time to maximum thrombus generation (TMG; min) and maximum thrombus generation (MTG; dynes cm(-2) s(-1)) and total thrombus generation (TTG; dyne cm(-2)) were registered. RESULTS: Platelets become more procoagulant, evaluated both by TEG and CAT during storage. The reduction in CAT lag time and the ttPeak correlated with a decrease in the TEG R time and TMG (P < 0.0001) as did the CAT peak thrombin generation and the TEG MTG (P = 0.0035). No correlation between ETP and TTG was found (P = 0.65). CONCLUSION: The kinetics of thrombin generation, as evaluated by CAT, correlates with the thrombus generation, as evaluated by thrombelastography and this may in part explain the clinical utility of the TEG in identifying clinically relevant coagulopathies, secondary to impaired thrombin generation
Udgivelsesdato: 2008/2
M3 - Journal article
SN - 0042-9007
VL - 94
SP - 113
EP - 118
JO - Vox Sanguinis
JF - Vox Sanguinis
IS - 2
ER -