Geometric analysis of CORA-based levelling osteotomy in the dog

James Edward Miles, Asger von Wenck, Michelle Brønniche Møller Nielsen, Ragnhild Gundersen

    Abstract

    Introduction
    CORA-based levelling osteotomy (CBLO) is a recent addition to techniques for management of cranial cruciate ligament deficiency in dogs (1,2). Preoperatively, careful identification of the proximal and distal tibial anatomic axes for correct localisation of the CORA, calculation of the required rotation to reduce the tibial plateau angle (TPA) to approximately 10°, and the chord length needed to achieve this rotation is necessary. Intraoperatively, these measurements must be judiciously transferred to the tibia to optimise outcome. The aim of this study was to model effects of inaccurate measurement transfer intraoperatively, for comparison with inter-surgeon differences during preoperative planning.
    Materials and methods
    Five landmarks (cranial and caudal tibial plateau, tibiotarsal joint centre, and craniocaudal diaphyseal midpoints at 1/3 and 2/3 the tibial length) necessary to define the tibial plateau, mechanical axis, and proximal and distal anatomical axes (2,3) were identified on 6 mediolateral tibial radiographs by 4 surgeons working independently. Measurements were made in ImageJ, using custom templates to aid localisation of landmarks, and copied to MS Excel. A custom macro was used to model rotational alignment of proximal and distal anatomical axes and the effects of mislocation of the angulation correction axis (ACA) by 3, 6 and 9 mm relative to the CORA at 10° steps through a full circle. The effects of rounding to nearest 0.5mm on chord length, and the effects of 0.5mm imprecision, on rotations around saw cuts of 12-30 mm radii were also simulated. The primary outcome measures were initial and final TPA, and associated interobserver errors. Secondary outcome measures were TPA error from optimal procedure TPA, and axis translation.
    Results
    Mean patient body mass was 32 kg (range 12-44 kg). Mean pre- and post-simulated CBLO TPA were 24.6° (SD 5.3°) and 9.3° (SD 0.7°): interobserver within-subject SD fell from 2.3° to 0.7° from pre to post. Mislocations of ACA by 3, 6 and 9 mm lead to mean TPA error ranges of 0.6°, 1.2° and 1.8°, and mean axis translation error ranges of 1.9, 3.9 and 5.9 mm, respectively. Chord length rounding produced mean absolute errors in TPA below 0.5°, whereas ±0.5mm chord length errors resulted in TPA error ranges of 1.6° to 4°, inversely related to saw radius.
    Conclusion
    Inter-surgeon variation in TPA measurement seems to be ameliorated by CBLO planning in this model. Modelled ACA positioning errors have relatively small effects on TPA compared to chord length errors. Larger saw radii result in smaller chord-related errors. Moving the ACA distally to accommodate a larger saw radius may reduce overall procedure errors.
    1.Raske M., Hulse D., Beale B., Saunders W.B., Kishi E., Kunze C. (2013) Stabilization of the CORA based leveling osteotomy for treatment of cranial cruciate ligament injury using a bone plate augmented with a headless compression screw. Veterinary Surgery 42: 759-764
    2.Piras A. (2012) Early clinical experiences with CORA based tibial plateau levelling osteotomy (CBTPLO) in toy breed dogs. Proceedings of the 16th ESVOT Congress, Bologna, Italy, 12th-15th September
    3.Petazzoni M., Jaeger G.H. (2008) Atlas of Clinical Goniometry and Radiographic Measurements of the Canine Pelvic Limb, 2 ed. Milano, Merial. pp 63-67
    Original languageEnglish
    Title of host publicationProceedings of the 19th ESVOT Congress and 5th WVOC Congress
    Number of pages1
    PublisherEuropean Society of Veterinary Orthopaedics and Traumatology
    Publication date12 Sept 2018
    Pages367
    Publication statusPublished - 12 Sept 2018
    Event19th European Society of Veterinary Orthopaedics and Traumatology Congress: 5th World Veterinary Orthopaedic Congress - Barcelona, Spain
    Duration: 12 Sept 201815 Sept 2018
    Conference number: 19

    Conference

    Conference19th European Society of Veterinary Orthopaedics and Traumatology Congress
    Number19
    Country/TerritorySpain
    CityBarcelona
    Period12/09/201815/09/2018

    Fingerprint

    Dive into the research topics of 'Geometric analysis of CORA-based levelling osteotomy in the dog'. Together they form a unique fingerprint.

    Cite this