Abstract
Electromembrane extraction (EME) was performed from aqueous samples and from aqueous samples containing methanol, ethanol, dimethyl sulfoxide, and acetonitrile. The basic drugs pethidine, haloperidol, nortriptyline, methadone and loperamide were used as model analytes. Reversed phase (C18) HPLC with UV (235. nm) and MS detection was used for analysis of the samples. With no organic solvent in the sample, maximum recoveries were obtained after 5-10. min. The maximum recoveries ranged between 83 and 95%. With 50% (v/v) methanol, ethanol, or dimethyl sulfoxide in the sample, recoveries were comparable to those from an aqueous sample, but the time required reaching maximum recovery increased to 15-25. min. With 2-nitrophenyl octyl ether (NPOE) as the supported liquid membrane (SLM), a stable EME system was obtained for 50% (v/v) methanol, 50% (v/v) ethanol, or 75% (v/v) dimethyl sulfoxide in the sample solution. On the other hand, the EME system was unstable with acetonitrile in the sample, as this solvent partly dissolved the SLM. In addition, acetonitrile migrated through the SLM and caused a volume expansion of the acceptor solution. Other SLMs were also tested (ethyl nitrobenzene, isopropyl nitrobenzene, and dodecyl nitrobenzene), but were inferior to NPOE. As a practical example, EME on dried blood spot extracts (80% methanol) were tested, and proved highly successful. These observations showed that EME can be an effective way of preparing aqueous samples containing substantial amounts of an organic solvent.
Original language | English |
---|---|
Journal | Journal of Chromatography A |
Volume | 1308 |
Pages (from-to) | 37-44 |
Number of pages | 8 |
ISSN | 0021-9673 |
Publication status | Published - 20 Sept 2013 |