Distortion of maximal elevator activity by unilateral premature tooth contact

Merete Bakke, Eigild Møller

103 Citations (Scopus)

Abstract

In four subjects the electrical activity in the anterior and posterior temporal and masseter muscles during maximal bite was recorded bilaterally with and without premature unilateral contact. Muscle activity was measured as the average level and the peak of the mean voltage with layers of strips of 0.05, 0.10, 0.15 and 2.0 mm, placed between first molars either on the left or the right side, and compared with the level of activity with undistrubed occlusion. Unilateral premature contact caused a significant asymmetry of action in all muscles under study with stronger activity ipsilaterally. With increasing thickness of the overlay the mean voltage decreased in parallel on both sides. We suggest that the asymmetry was caused by larger spindle afferent activity on the ipsilateral as compared to the contralateral side, and that the all-over decrease of muscle activity was due to a gradual reduction of activity from periodontal pressoreceptors.
Original languageEnglish
JournalScandinavian Journal of Dental Research
Volume88
Issue number1
Pages (from-to)67-75
Number of pages9
ISSN0029-845X
Publication statusPublished - 1980

Keywords

  • Adult
  • Dental Occlusion, Traumatic
  • Dental Stress Analysis
  • Electromyography
  • Female
  • Humans
  • Male
  • Malocclusion
  • Masseter Muscle
  • Masticatory Muscles
  • Muscle Contraction
  • Temporal Muscle

Fingerprint

Dive into the research topics of 'Distortion of maximal elevator activity by unilateral premature tooth contact'. Together they form a unique fingerprint.

Cite this