Development and validation of the OMERACT rheumatoid arthritis magnetic resonance tenosynovitis scoring system in a multireader exercise

Daniel Glinatsi*, Paul Bird, Frédérique Gandjbakhch, Espen A. Haavardsholm, Charles G. Peterfy, Edward M. Vital, Paul Emery, Philip G. Conaghan, Mikkel Østergaard

*Corresponding author for this work
19 Citations (Scopus)

Abstract

Objective: To develop and validate a magnetic resonance imaging (MRI) tenosynovitis (TS) score for tendons at the wrist and metacarpophalangeal (MCP) joint levels in patients with rheumatoid arthritis (RA). Methods: Axial T1-weighted precontrast and postcontrast fat-saturated MR image sets of the hands of 43 patients with RA initiating rituximab therapy were obtained at baseline and after 14, 26, 38, or 52 weeks. The MR images were scored twice by 4 readers. Nine tendon compartments of the wrist and 4 flexor tendon compartments at the MCP joints were assessed. Tenosynovitis was scored as follows: 0: No; 1: < 1.5 mm; 2: ≥ 1.5 mm but < 3 mm; 3: ≥ 3 mm peritendinous effusion and/or postcontrast enhancement. Intrareader and interreader intraclass correlation coefficients (ICC), smallest detectable change (SDC), percentage of exact and close agreement (PEA/PCA), and standardized response mean (SRM) were calculated. Results: Intrareader and interreader ICC for status and change scores were very good (≥ 0.80) for total scores for all readers. Intrareader SDC was ≤ 3.0 and interreader SDC was < 2.0. The overall PEA/PCA intrareader and interreader agreements for change scores in all tendons were 73.8%/97.6% and 47.9%/85.0%, respectively. Average SRM was moderate for total scores and 60.5% of the patients had a tenosynovitis change score ≥ SDC. Conclusion: The TS score showed high intrareader and interreader agreement for wrist and finger tendons, with moderate responsiveness, and the majority of the patients showed a change above the SDC. This scoring system may be included as a component of the RAMRIS. The Journal of Rheumatology

Original languageEnglish
JournalJournal of Rheumatology
Volume44
Issue number11
Pages (from-to)1688-1693
Number of pages6
ISSN0315-162X
DOIs
Publication statusPublished - 1 Nov 2017

Keywords

  • Magnetic resonance imaging
  • Omeract
  • Tenosynovitis rheumatoid arthritis

Fingerprint

Dive into the research topics of 'Development and validation of the OMERACT rheumatoid arthritis magnetic resonance tenosynovitis scoring system in a multireader exercise'. Together they form a unique fingerprint.

Cite this