Abstract
Broad-bandwidth, high-spectral-resolution optical detection of human breath has identified multiple important biomarkers correlated with specific diseases and metabolic processes. This optical-frequency-comb-based breath analysis system comes with excellent performance in all criteria: high detection sensitivity, ability to identify and distinguish a large number of analytes, and simultaneous, real-time information processing. We demonstrate a minimum detectable absorption of 8 x 10-10cm-1, a spectral resolution of 800 MHz, and 200 nm of spectral coverage from 1.5 to 1.7 µm where strong and unique molecular fingerprints exist for many biomarkers. We present a series of breath measurements including stable isotope ratios of CO2, breath concentrations of CO, and the presence of trace concentrations of NH3 in high concentrations of H2O.
Udgivelsesdato: 02.05
Udgivelsesdato: 02.05
Original language | English |
---|---|
Journal | Optics Express |
Volume | 16 |
Issue number | 4 |
Pages (from-to) | 2387-2397 |
Number of pages | 10 |
ISSN | 1094-4087 |
DOIs | |
Publication status | Published - 2008 |