Antiarrhythmic and electrophysiologic effects of flecainide on acutely induced atrial fibrillation in healthy horses

Maria Mathilde Haugaard, S. Pehrson, Helena Carstensen, Mette Flethøj Madsen, Eva Zander Hesselkilde, K. F. Præstegaard, J. G. Diness, M. Grunnet, Thomas Jespersen, Rikke Buhl

19 Citations (Scopus)
1434 Downloads (Pure)

Abstract

Background: Only few pharmacologic compounds have been validated for treatment of atrial fibrillation (AF) in horses. Studies investigating the utility and safety of flecainide to treat AF in horses have produced conflicting results, and the antiarrhythmic mechanisms of flecainide are not fully understood. Objectives: To study the potential of flecainide to terminate acutely induced AF of short duration (≥15 minutes), to examine flecainide-induced changes in AF duration and AF vulnerability, and to investigate the in vivo effects of flecainide on right atrial effective refractory period, AF cycle length, and ventricular depolarization and repolarization. Animals: Nine Standardbred horses. Eight received flecainide, 3 were used as time-matched controls, 2 of which also received flecainide. Methods: Prospective study. The antiarrhythmic and electrophysiologic effects of flecainide were based on 5 parameters: ability to terminate acute pacing-induced AF (≥15 minutes), and drug-induced changes in atrial effective refractory period, AF duration, AF vulnerability, and ventricular depolarization and repolarization times. Parameters were assessed at baseline and after flecainide by programmed electrical stimulation methods. Results: Flecainide terminated all acutely induced AF episodes (n = 7); (AF duration, 21 ± 5 minutes) and significantly decreased the AF duration, but neither altered atrial effective refractory period nor AF vulnerability significantly. Ventricular repolarization time was prolonged between 8 and 20 minutes after initiation of flecainide infusion, but no ventricular arrhythmias were detected. Conclusions and Clinical Importance: Flecainide had clear antiarrhythmic properties in terminating acute pacing-induced AF, but showed no protective properties against immediate reinduction of AF. Flecainide caused temporary prolongation in the ventricular repolarization, which may be a proarrhythmic effect.

Original languageEnglish
JournalJournal of Veterinary Internal Medicine
Volume29
Issue number1
Pages (from-to)339-347
Number of pages9
ISSN0891-6640
DOIs
Publication statusPublished - 1 Jan 2015

Fingerprint

Dive into the research topics of 'Antiarrhythmic and electrophysiologic effects of flecainide on acutely induced atrial fibrillation in healthy horses'. Together they form a unique fingerprint.

Cite this