T1 - Accurate Angle Estimator for High-Frame-Rate 2-D Vector Flow Imaging
AU - Villagomez Hoyos, Carlos Armando
AU - Stuart, Matthias Bo
AU - Hansen, Kristoffer Lindskov
AU - Nielsen, Michael Bachmann
AU - Jensen, Jorgen Arendt
PY - 2016/6
Y1 - 2016/6
N2 - This paper presents a novel approach for estimating 2-D flow angles using a high-frame-rate ultrasound method. The angle estimator features high accuracy and low standard deviation (SD) over the full 360° range. The method is validated on Field II simulations and phantom measurements using the experimental ultrasound scanner SARUS and a flow rig before being tested in vivo. An 8-MHz linear array transducer is used with defocused beam emissions. In the simulations of a spinning disk phantom, a 360° uniform behavior on the angle estimation is observed with a median angle bias of 1.01° and a median angle SD of 1.8°. Similar results are obtained on a straight vessel for both simulations and measurements, where the obtained angle biases are below 1.5° with SDs around 1°. Estimated velocity magnitudes are also kept under 10% bias and 5% relative SD in both simulations and measurements. An in vivo measurement is performed on a carotid bifurcation of a healthy individual. A 3-s acquisition during three heart cycles is captured. A consistent and repetitive vortex is observed in the carotid bulb during systoles.
AB - This paper presents a novel approach for estimating 2-D flow angles using a high-frame-rate ultrasound method. The angle estimator features high accuracy and low standard deviation (SD) over the full 360° range. The method is validated on Field II simulations and phantom measurements using the experimental ultrasound scanner SARUS and a flow rig before being tested in vivo. An 8-MHz linear array transducer is used with defocused beam emissions. In the simulations of a spinning disk phantom, a 360° uniform behavior on the angle estimation is observed with a median angle bias of 1.01° and a median angle SD of 1.8°. Similar results are obtained on a straight vessel for both simulations and measurements, where the obtained angle biases are below 1.5° with SDs around 1°. Estimated velocity magnitudes are also kept under 10% bias and 5% relative SD in both simulations and measurements. An in vivo measurement is performed on a carotid bifurcation of a healthy individual. A 3-s acquisition during three heart cycles is captured. A consistent and repetitive vortex is observed in the carotid bulb during systoles.
KW - Journal Article
U2 - 10.1109/TUFFC.2016.2551689
DO - 10.1109/TUFFC.2016.2551689
M3 - Journal article
C2 - 27093598
SN - 0885-3010
VL - 63
SP - 842
EP - 853
JO - I E E E Transactions on Ultrasonics, Ferroelectrics and Frequency Control
JF - I E E E Transactions on Ultrasonics, Ferroelectrics and Frequency Control
IS - 6
ER -