TY - JOUR
T1 - Validity of the Acti4 method for detection of physical activity types in free-living settings
T2 - comparison with video analysis
AU - Stemland, Ingunn
AU - Ingebrigtsen, Jørgen
AU - Christiansen, Caroline S
AU - Jensen, Bente Rona
AU - Hanisch, Christiana
AU - Skotte, Jørgen
AU - Holtermann, Andreas
N1 - CURIS 2015 NEXS 037
PY - 2015/6/3
Y1 - 2015/6/3
N2 - This study examined the ability of the Acti4 software for identifying physical activity types from accelerometers during free-living with different levels of movement complexity compared with video observations. Nineteen aircraft cabin cleaners with ActiGraph GT3X+ accelerometer at the thigh and hip performed one semi-standardised and two non-standardised sessions (outside and inside aircraft) with different levels of movement complexity during working hours. The sensitivity for identifying different activity types was 75.4-99.4% for the semi-standardised session, 54.6-98.5% outside the aircraft and 49.9-90.2% inside the aircraft. The specificity was above 90% for all activities, except 'moving' inside the aircraft. These findings indicate that Acti4 provides good estimates of time spent in different activity types during semi-standardised conditions, and for sitting, standing and walking during non-standardised conditions with normal level of movement complexity. The Acti4 software may be a useful tool for researchers and practitioners in the field of ergonomics, occupational and public health. Practitioner Summary: Being inexpensive, small, water-resistant and without wires, the ActiGraph GT3X+ by applying the Acti4 software may be a useful tool for long-term field measurements of physical activity types for researchers and practitioners in the field of ergonomics, occupational and public health.
AB - This study examined the ability of the Acti4 software for identifying physical activity types from accelerometers during free-living with different levels of movement complexity compared with video observations. Nineteen aircraft cabin cleaners with ActiGraph GT3X+ accelerometer at the thigh and hip performed one semi-standardised and two non-standardised sessions (outside and inside aircraft) with different levels of movement complexity during working hours. The sensitivity for identifying different activity types was 75.4-99.4% for the semi-standardised session, 54.6-98.5% outside the aircraft and 49.9-90.2% inside the aircraft. The specificity was above 90% for all activities, except 'moving' inside the aircraft. These findings indicate that Acti4 provides good estimates of time spent in different activity types during semi-standardised conditions, and for sitting, standing and walking during non-standardised conditions with normal level of movement complexity. The Acti4 software may be a useful tool for researchers and practitioners in the field of ergonomics, occupational and public health. Practitioner Summary: Being inexpensive, small, water-resistant and without wires, the ActiGraph GT3X+ by applying the Acti4 software may be a useful tool for long-term field measurements of physical activity types for researchers and practitioners in the field of ergonomics, occupational and public health.
U2 - 10.1080/00140139.2014.998724
DO - 10.1080/00140139.2014.998724
M3 - Journal article
C2 - 25588819
SN - 0014-0139
VL - 58
SP - 953
EP - 965
JO - Ergonomics
JF - Ergonomics
IS - 6
ER -