T1 - The impact of an electronic monitoring and reminder device on patient compliance with antihypertensive therapy
T2 - a randomized controlled trial
AU - Christensen, Arne
AU - Christrup, Lona Louring
AU - Fabricius, Paul Erik
AU - Chrostowska, Marzena
AU - Wronka, Michal
AU - Narkiewicz, Krzysztof
AU - Hansen, Ebba Holme
PY - 2010/1
Y1 - 2010/1
N2 - BACKGROUND: High blood pressure (BP) significantly increases overall cardiovascular risk, the incidence of ischemic heart disease and stroke. One of the most important causes of insufficient BP control is low treatment compliance. Reminders and electronic compliance monitoring have been shown to be effective in improving patient compliance to some extent, but the combined effect has not been documented. OBJECTIVE: To assess the impact of an electronic reminder and monitoring device on patient compliance and BP control. METHODS: All patients received medical treatment with telmisartan once daily and were randomized to either electronic compliance monitoring with a reminder and monitoring device or standard therapy for 6 months. Both groups were crossed over after 6 months. Intervention effectiveness was assessed using self-reported compliance and BP. RESULTS: Data from 398 patients were analysed. In the first half of the study, patients using the device reported 91% compliance versus 85% in the control group. This difference diminished after crossover (88 versus 86%). BP was not affected. Electronic monitoring data on compliance revealed taking, dosing and timing compliance between 45 and 52% in study group 1, and between 32 and 38% in study group 2. CONCLUSION: The Helping Hand reminder device was most suitable if used for newly diagnosed hypertensive patients, when it improved compliance by 6%. With the present medical treatment, the device does not have any influence on BP control, but with less forgiving medications, the device might make a significant difference. The use of the device can be an easy and effective way to improve compliance in selected patients.
AB - BACKGROUND: High blood pressure (BP) significantly increases overall cardiovascular risk, the incidence of ischemic heart disease and stroke. One of the most important causes of insufficient BP control is low treatment compliance. Reminders and electronic compliance monitoring have been shown to be effective in improving patient compliance to some extent, but the combined effect has not been documented. OBJECTIVE: To assess the impact of an electronic reminder and monitoring device on patient compliance and BP control. METHODS: All patients received medical treatment with telmisartan once daily and were randomized to either electronic compliance monitoring with a reminder and monitoring device or standard therapy for 6 months. Both groups were crossed over after 6 months. Intervention effectiveness was assessed using self-reported compliance and BP. RESULTS: Data from 398 patients were analysed. In the first half of the study, patients using the device reported 91% compliance versus 85% in the control group. This difference diminished after crossover (88 versus 86%). BP was not affected. Electronic monitoring data on compliance revealed taking, dosing and timing compliance between 45 and 52% in study group 1, and between 32 and 38% in study group 2. CONCLUSION: The Helping Hand reminder device was most suitable if used for newly diagnosed hypertensive patients, when it improved compliance by 6%. With the present medical treatment, the device does not have any influence on BP control, but with less forgiving medications, the device might make a significant difference. The use of the device can be an easy and effective way to improve compliance in selected patients.
KW - Former Faculty of Pharmaceutical Sciences
U2 - 10.1097/hjh.0b013e328331b718
DO - 10.1097/hjh.0b013e328331b718
M3 - Journal article
C2 - 19770778
SN - 0263-6352
VL - 28
SP - 194
EP - 200
JO - Journal of Hypertension
JF - Journal of Hypertension
IS - 1
ER -