Reperfusion of liver graft during transplantation: Techniques used in transplant centres within Eurotransplant and meta-analysis of the literature

G. Manzini, M. Kremer, P. Houben, H. Binder, P. Schemmer, Matthias Gondan, W.O. Bechstein, Thomas Becker, G.A. Berlakovich, H. Friess, M. Guba, W. Hohenberger, J.N.M. Ijzermans, S. Jonas, J.C. Kalff, E. Klar, J. Klempnauer, J. Lerut, Hanne Lippert, T. LorfS. Nadalin, B. Nashan, G. Otto, A. Paul, J. Pirenne, J. Pratschke, J. Ringers, X. Rogiers, M.K. Schilling, D. Seehofer, N. Senninger, U. Settmacher, D.L. Stippel, K. Tscheliessnigg, D. Ysebaert

21 Citationer (Scopus)

Abstract

It remains unclear which liver graft reperfusion technique leads to the best outcome following transplantation. An online survey was sent to all transplant centres (n = 37) within Eurotransplant (ET) to collect information on their technique used for reperfusion of liver grafts. Furthermore, a systematic review of all literature was performed and a meta-analysis was conducted based on patients' mortality, number of retransplantations and incidence of biliary complications, depending on the technique used. Of the 28 evaluated centres, 11 (39%) reported performing simultaneous reperfusion (SIMR), 13 (46%) perform initial portal vein reperfusion (IPR), 1 (4%) performs an initial hepatic artery reperfusion (IAR) and 3 (11%) perform retrograde reperfusion (RETR). In 21 centres (75%), one reperfusion technique is used as a standard, but in only one centre is this decision based on available literature. Twenty centres (71%) said they would agree to participate in randomized controlled trials (RCT) if required. For meta-analysis, IAR vs. IPR, SIMR vs. IPR and RETR vs. IPR were compared. There was no difference between any of the techniques compared. There is no consensus on a preferable reperfusion technique. Available evidence does not help in the decision-making process. There is thus an urgent need for multicentric RCTs.
OriginalsprogEngelsk
TidsskriftTransplant International
Vol/bind26
Udgave nummer5
Sider (fra-til)508-516
Antal sider9
ISSN0934-0874
DOI
StatusUdgivet - 1 maj 2013
Udgivet eksterntJa

Fingeraftryk

Dyk ned i forskningsemnerne om 'Reperfusion of liver graft during transplantation: Techniques used in transplant centres within Eurotransplant and meta-analysis of the literature'. Sammen danner de et unikt fingeraftryk.

Citationsformater