TY - GEN
T1 - Quantum dots as handles for optical manipulation
AU - Pedersen, Liselotte Jauffred
AU - Sletmoen, Marit
AU - Czerwinski, Fabian
AU - Oddershede, Lene Broeng
PY - 2010/8/27
Y1 - 2010/8/27
N2 - Individual colloidal quantum dots can be optically trapped and manipulated by a single infrared laser beam operated at low laser powers.1, 2 If the absorption spectrum and the emission wavelength of the trapping laser are appropriately chosen, the trapping laser light can act as a source for two-photon excitation of the trapped quantum dot. This eliminates the need for an additional excitation laser in experiments where individual quantum dots are used both as force transducers and for visualization of the system. To use quantum dots as handles for quantitative optical force transduction, it is crucial to perform a precise force calibration. Here, we present an Allan variance analysis3 of individual optically trapped quantum dots and show that the optimal measurement time for experiments involving individual quantum dots is on the order of 0.3 seconds. Due to their small size and strong illumination, quantum dots are optimal for single molecule assays where, optimally, the presence of the tracer particle should not dominate the dynamics of the system. As an example, we investigated the thermal fluctuations of a DNA tether using an individual colloidal quantum dot as marker, this being the smallest tracer for tethered particle method reported.
AB - Individual colloidal quantum dots can be optically trapped and manipulated by a single infrared laser beam operated at low laser powers.1, 2 If the absorption spectrum and the emission wavelength of the trapping laser are appropriately chosen, the trapping laser light can act as a source for two-photon excitation of the trapped quantum dot. This eliminates the need for an additional excitation laser in experiments where individual quantum dots are used both as force transducers and for visualization of the system. To use quantum dots as handles for quantitative optical force transduction, it is crucial to perform a precise force calibration. Here, we present an Allan variance analysis3 of individual optically trapped quantum dots and show that the optimal measurement time for experiments involving individual quantum dots is on the order of 0.3 seconds. Due to their small size and strong illumination, quantum dots are optimal for single molecule assays where, optimally, the presence of the tracer particle should not dominate the dynamics of the system. As an example, we investigated the thermal fluctuations of a DNA tether using an individual colloidal quantum dot as marker, this being the smallest tracer for tethered particle method reported.
U2 - 10.1117/12.860486
DO - 10.1117/12.860486
M3 - Conference article
SN - 1605-7422
VL - 7762
JO - Proceedings of SPIE, the International Society for Optical Engineering
JF - Proceedings of SPIE, the International Society for Optical Engineering
ER -