Plaque characterization in ex vivo MRI evaluated by dense 3D correspondence with histology

Arna van Engelen, Marleen de Bruijne, Stefan Klein, Hence Verhagen, Harold Groen, Jolanda Wentzel, Aad van der Lugt, Wiro Niessen

2 Citationer (Scopus)

Abstract

Automatic quantification of carotid artery plaque composition is important in the development of methods that distinguish vulnerable from stable plaques. MRI has shown to be capable of imaging different components noninvasively. We present a new plaque classification method which uses 3D registration of histology data with ex vivo MRI data, using non-rigid registration, both for training and evaluation. This is more objective than previously presented methods, as it eliminates selection bias that is introduced when 2D MRI slices are manually matched to histological slices before evaluation. Histological slices of human atherosclerotic plaques were manually segmented into necrotic core, fibrous tissue and calcification. Classification of these three components was voxelwise evaluated. As features the intensity, gradient magnitude and Laplacian in four MRI sequences after different degrees of Gaussian smoothing, and the distances to the lumen and the outer vessel wall, were used. Performance of linear and quadratic discriminant classifiers for different combinations of features was evaluated. Best accuracy (72.5 ± 7.7%) was reached with the linear classifier when all features were used. Although this was only a minor improvement to the accuracy of a classifier that only included the intensities and distance features (71.6 ± 7.9%), the difference was statistically significant (paired t-test, p<0.05). Good sensitivity and specificity for calcification was reached (83% and 95% respectively), however, differentiation between fibrous (sensitivity 85%, specificity 60%) and necrotic tissue (sensitivity 49%, specificity 89%) was more difficult.

OriginalsprogEngelsk
TitelMedical Imaging 2011 : computer-aided diagnosis
RedaktørerRonald M. Summers, Bram van Ginneken
Antal sider11
Vol/bindPart One
ForlagSPIE - International Society for Optical Engineering
Publikationsdato2011
Artikelnummer796329
ISBN (Elektronisk)9780819485052
DOI
StatusUdgivet - 2011
BegivenhedMedical Imaging 2011: Computer-Aided Diagnosis - Lake Buena Vista, USA
Varighed: 15 feb. 201115 feb. 2011

Konference

KonferenceMedical Imaging 2011
Land/OmrådeUSA
ByLake Buena Vista
Periode15/02/201115/02/2011
NavnProgress in Biomedical Optics and Imaging
Nummer32
Vol/bind12
ISSN1605-7422

Fingeraftryk

Dyk ned i forskningsemnerne om 'Plaque characterization in ex vivo MRI evaluated by dense 3D correspondence with histology'. Sammen danner de et unikt fingeraftryk.

Citationsformater