Abstract
Hypoxia during haemodialysis, mainly acetate, has been reported several times. In our study we have monitored oxygen status during 258 bicarbonate haemodialyses. A significant drop below 80 mmHg in mean oxygen tension occurred. Mean oxygen saturation reflected this drop but did not reach levels below 90%. The mean oxygen concentration was on the whole critical low, though slightly increasing during each haemodialysis session due to ultrafiltration. It is concluded that both hypoxia and hypoxaemia do occur during bicarbonate haemodialysis. To a group of patients generally having limited cardiac reserves, a poor oxygen status is a potentially serious complication to haemodialysis. Monitoring oxygen status is thus advisable.
Originalsprog | Engelsk |
---|---|
Tidsskrift | Acta Anaesthesiologica Scandinavica |
Vol/bind | 107 |
Sider (fra-til) | 195-200 |
Antal sider | 6 |
ISSN | 0001-5172 |
Status | Udgivet - sep. 1995 |