TY - JOUR
T1 - Objective and subjective outcome of a new transcutaneous bone conduction hearing device
T2 - Half-year follow-up of the first 12 nordic implantations
AU - Eberhard, Kristine Elisabeth
AU - Olsen, Steen Østergaard
AU - Miyazaki, Hidemi
AU - Bille, Michael
AU - Caye-Thomasen, Per
PY - 2016
Y1 - 2016
N2 - Objective: To examine the objective and subjective outcome of a new transcutaneous bone conduction hearing device. Study Design: Prospective, consecutive case series. Patients: Twelve patients were implanted. Eight patients had a conductive/mixed (con/mix) hearing loss. Four had single sided deafness. Main Outcome Measures: At half-year follow-up, aided and unaided sound field hearing was evaluated by 1) warble tone thresholds, 2) pure-Tone average (PTA4), 3) speech discrimination score (SDS) in quiet, and 4) speech reception threshold 50% at 70 dB SPL noise level (SRT50%). Subjective outcome was evaluated by three questionnaires: 1) International Outcome Inventory for Hearing AIDS, 2) Speech, Spatial and Qualities of Hearing Scale 12, and 3) a questionnaire on frequency and duration of use. Results: No major complications occurred. The mean aided PTA4 was lowered by 23 dB. SDS was increased by 40% at 50 dB, by 34% at 65 dB, and by 12% at 80 dB SPL. SRT50% in noise improved 5.2 dB. 58% of the patients used the device daily and 83% at least 5 days a week. 50% used the device-8 hours and 75%-4 hours a day. Mean International Outcome Inventory for Hearing AIDS score was 3.7, corresponding to beneficial outcome. In Speech, Spatial and Qualities of Hearing Scale 12, ''quality of hearing'' scored especially high. The con/mix hearing loss group showed larger benefit especially in SDS, SRT50% in noise and the subjective evaluations, whereas frequency and duration of use were similar. Conclusion: This study on the first 12 Nordic patients implanted with a new transcutaneous bone conduction hearing device demonstrates significant objective, as well as subjective hearing benefit. Patient satisfaction was high, as was the frequency of use.
AB - Objective: To examine the objective and subjective outcome of a new transcutaneous bone conduction hearing device. Study Design: Prospective, consecutive case series. Patients: Twelve patients were implanted. Eight patients had a conductive/mixed (con/mix) hearing loss. Four had single sided deafness. Main Outcome Measures: At half-year follow-up, aided and unaided sound field hearing was evaluated by 1) warble tone thresholds, 2) pure-Tone average (PTA4), 3) speech discrimination score (SDS) in quiet, and 4) speech reception threshold 50% at 70 dB SPL noise level (SRT50%). Subjective outcome was evaluated by three questionnaires: 1) International Outcome Inventory for Hearing AIDS, 2) Speech, Spatial and Qualities of Hearing Scale 12, and 3) a questionnaire on frequency and duration of use. Results: No major complications occurred. The mean aided PTA4 was lowered by 23 dB. SDS was increased by 40% at 50 dB, by 34% at 65 dB, and by 12% at 80 dB SPL. SRT50% in noise improved 5.2 dB. 58% of the patients used the device daily and 83% at least 5 days a week. 50% used the device-8 hours and 75%-4 hours a day. Mean International Outcome Inventory for Hearing AIDS score was 3.7, corresponding to beneficial outcome. In Speech, Spatial and Qualities of Hearing Scale 12, ''quality of hearing'' scored especially high. The con/mix hearing loss group showed larger benefit especially in SDS, SRT50% in noise and the subjective evaluations, whereas frequency and duration of use were similar. Conclusion: This study on the first 12 Nordic patients implanted with a new transcutaneous bone conduction hearing device demonstrates significant objective, as well as subjective hearing benefit. Patient satisfaction was high, as was the frequency of use.
KW - Bone anchored hearing AIDS
KW - Bone anchored hearing systems
KW - Bone conduction hearing devices
KW - Conductive hearing loss
KW - Mixed hearing loss
KW - Single sided deafness.
U2 - 10.1097/MAO.0000000000000969
DO - 10.1097/MAO.0000000000000969
M3 - Journal article
C2 - 26859460
AN - SCOPUS:84958942967
SN - 1531-7129
VL - 37
SP - 267
EP - 275
JO - Otology & Neurotology
JF - Otology & Neurotology
IS - 3
ER -