Abstract
We measured neutralizing antibodies (NABs) and the in vivo biologic response to interferon-beta on neopterin and beta(2)-microglobulin blood levels. All NAB-negative patients had an in vivo biologic response (full or partial), whereas all high-level positive patients had no response. High-level NAB patients had more MRI activity than NAB-negative patients (p = 0.031). Patients with a full response had less MRI activity than patients without biologic response (p = 0.032).
Originalsprog | Engelsk |
---|---|
Tidsskrift | Neurology |
Vol/bind | 67 |
Udgave nummer | 9 |
Sider (fra-til) | 1681-83 |
ISSN | 0028-3878 |
DOI | |