TY - JOUR
T1 - Massively parallel pyrosequencing of the mitochondrial genome with the 454 methodology in forensic genetics
AU - Mikkelsen, Martin
AU - Frank-Hansen, Rune
AU - Hansen, Anders Johannes
AU - Morling, Niels
N1 - Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
PY - 2014/9
Y1 - 2014/9
N2 - RESULTS: of sequencing of whole mitochondrial genome, HV1 and HV2 DNA with the second generation system (SGS) Roche 454 GS Junior were compared with results of Sanger sequencing and SNP typing with SNaPshot single base extension detected with MALDI-TOF and capillary electrophoresis. We investigated the performance of the software analysis of the data, reproducibility, ability to sequence homopolymeric regions, detection of mixtures and heteroplasmy as well as the implications of the depth of coverage. We found full reproducibility between samples sequenced twice with SGS. We found close to full concordance between the mtDNA sequences of 26 samples obtained with (1) the 454 SGS method using a depth of coverage above 100 and (2) Sanger sequencing and SNP typing. The discrepancies were primarily observed in homopolymeric regions. The 454 SGS method was able to sequence 95% of the reads correctly in homopolymers up to 4 bases, and up to 6 bases could be sequenced with similar success if the results were carefully, visually inspected. The 454 technology was able to detect mixtures or heteroplasmy of approximately 10%. We detected previously unreported heteroplasmy in the GM9947A component of the NIST human mitochondrial DNA SRM-2392 standard reference material.
AB - RESULTS: of sequencing of whole mitochondrial genome, HV1 and HV2 DNA with the second generation system (SGS) Roche 454 GS Junior were compared with results of Sanger sequencing and SNP typing with SNaPshot single base extension detected with MALDI-TOF and capillary electrophoresis. We investigated the performance of the software analysis of the data, reproducibility, ability to sequence homopolymeric regions, detection of mixtures and heteroplasmy as well as the implications of the depth of coverage. We found full reproducibility between samples sequenced twice with SGS. We found close to full concordance between the mtDNA sequences of 26 samples obtained with (1) the 454 SGS method using a depth of coverage above 100 and (2) Sanger sequencing and SNP typing. The discrepancies were primarily observed in homopolymeric regions. The 454 SGS method was able to sequence 95% of the reads correctly in homopolymers up to 4 bases, and up to 6 bases could be sequenced with similar success if the results were carefully, visually inspected. The 454 technology was able to detect mixtures or heteroplasmy of approximately 10%. We detected previously unreported heteroplasmy in the GM9947A component of the NIST human mitochondrial DNA SRM-2392 standard reference material.
U2 - 10.1016/j.fsigen.2014.03.014
DO - 10.1016/j.fsigen.2014.03.014
M3 - Journal article
C2 - 24879032
SN - 1878-0326
VL - 12
SP - 30
EP - 37
JO - Forensic science international. Genetics
JF - Forensic science international. Genetics
ER -