TY - JOUR
T1 - Diagnostic performance of Schistosoma real-time PCR in urine samples from Kenyan children infected with Schistosoma haematobium
T2 - day-to-day variation and follow-up after praziquantel treatment
AU - Vinkeles Melchers, Natalie V. S.
AU - van Dam, Govert J.
AU - Shaproski, David
AU - Kahama, Anthony I.
AU - Brienen, Eric A. T.
AU - Vennervald, Birgitte J
AU - van Lieshout, Lisette
PY - 2014/4
Y1 - 2014/4
N2 - BACKGROUND: In an effort to enhance accuracy of diagnosis of Schistosoma haematobium, this study explores day-to-day variability and diagnostic performance of real-time PCR for detection and quantification of Schistosoma DNA compared to other diagnostic tools in an endemic area before and after treatment.METHODOLOGY: Previously collected urine samples (N = 390) from 114 preselected proven parasitological and/or clinical S. haematobium positive Kenyan schoolchildren were analyzed by a Schistosoma internal transcribed spacer-based real-time PCR after 14 years of storage. Pre-treatment day-to-day fluctuations of PCR and microscopy over three consecutive days were measured for 24 children using intra-class correlation coefficient. A combined 'gold standard' (PCR and/or microscopy positive) was used to measure sensitivity and negative predictive value (NPV) of several diagnostic tools at baseline, two and 18 months post-treatment with praziquantel.PRINCIPAL FINDINGS: All 24 repeatedly tested children were PCR-positive over three days with little daily variation in median Ct-values, while 83.3% were found to be egg-positive for S. haematobium at day 1 and 75.0% at day 2 and 3 pre-treatment, signifying daily fluctuations in microscopy diagnosis. Of all 114 preselected schoolchildren, repeated microscopic measurements were required to detect 96.5% versus 100% of positive pre-treatment cases by single PCR. At two months post-treatment, microscopy and PCR detected 22.8% versus 69.3% positive children, respectively. Based on the 'gold standard', PCR showed high sensitivity (>92%) as compared to >31% sensitivity for microscopy, both pre- and post-treatment.CONCLUSIONS/SIGNIFICANCE: Detection and quantification of Schistosoma DNA in urine by real-time PCR was shown to be a powerful and specific diagnostic tool for detection of S. haematobium infections, with less day-to-day variation and higher sensitivity compared to microscopy. The superior performance of PCR before, and two and 18 months post-treatment provides a compelling argument for PCR as an accurate and reproducible tool for monitoring treatment efficacy.
AB - BACKGROUND: In an effort to enhance accuracy of diagnosis of Schistosoma haematobium, this study explores day-to-day variability and diagnostic performance of real-time PCR for detection and quantification of Schistosoma DNA compared to other diagnostic tools in an endemic area before and after treatment.METHODOLOGY: Previously collected urine samples (N = 390) from 114 preselected proven parasitological and/or clinical S. haematobium positive Kenyan schoolchildren were analyzed by a Schistosoma internal transcribed spacer-based real-time PCR after 14 years of storage. Pre-treatment day-to-day fluctuations of PCR and microscopy over three consecutive days were measured for 24 children using intra-class correlation coefficient. A combined 'gold standard' (PCR and/or microscopy positive) was used to measure sensitivity and negative predictive value (NPV) of several diagnostic tools at baseline, two and 18 months post-treatment with praziquantel.PRINCIPAL FINDINGS: All 24 repeatedly tested children were PCR-positive over three days with little daily variation in median Ct-values, while 83.3% were found to be egg-positive for S. haematobium at day 1 and 75.0% at day 2 and 3 pre-treatment, signifying daily fluctuations in microscopy diagnosis. Of all 114 preselected schoolchildren, repeated microscopic measurements were required to detect 96.5% versus 100% of positive pre-treatment cases by single PCR. At two months post-treatment, microscopy and PCR detected 22.8% versus 69.3% positive children, respectively. Based on the 'gold standard', PCR showed high sensitivity (>92%) as compared to >31% sensitivity for microscopy, both pre- and post-treatment.CONCLUSIONS/SIGNIFICANCE: Detection and quantification of Schistosoma DNA in urine by real-time PCR was shown to be a powerful and specific diagnostic tool for detection of S. haematobium infections, with less day-to-day variation and higher sensitivity compared to microscopy. The superior performance of PCR before, and two and 18 months post-treatment provides a compelling argument for PCR as an accurate and reproducible tool for monitoring treatment efficacy.
KW - Adolescent
KW - Animals
KW - Anthelmintics
KW - Child
KW - DNA, Ribosomal Spacer
KW - Drug Monitoring
KW - Female
KW - Humans
KW - Kenya
KW - Male
KW - Microscopy
KW - Parasitology
KW - Praziquantel
KW - Predictive Value of Tests
KW - Real-Time Polymerase Chain Reaction
KW - Retrospective Studies
KW - Schistosoma haematobium
KW - Schistosomiasis haematobia
KW - Sensitivity and Specificity
KW - Urine
U2 - 10.1371/journal.pntd.0002807
DO - 10.1371/journal.pntd.0002807
M3 - Journal article
C2 - 24743389
SN - 1935-2727
VL - 8
JO - P L o S Neglected Tropical Diseases (Print)
JF - P L o S Neglected Tropical Diseases (Print)
IS - 4
M1 - e2807
ER -