Abstract
Abstract:
Purpose: To demonstrate the workflow used in the evaluation of Post Mortem MSCT as part of dental identification in single and possibly multiple fatalities. Material and method: The workflow in a couple of cases from the Section of
Forensic Pathology in Copenhagen, Denmark is used to illustrate how the use of OsiriX® DICOM Viewer and its tools can be applied to overcome some of the problems contained in MSCT images compared to the usual
ortopantomograms used in forensic odontology for identification. Results, discussion and conclusion: The combined use of tomograms (slices), 2D Mean Intensity Projection and 3D MIP/VR (3D Maximum Intensity Projection/Volume
Rendering) was found to give a very useful first view for the forensic odontological evaluation, and the combined use overcomes many of the problems which are contained in the Post Mortem MSCT procedure compared to regular
X-ray examination technique. It is also possible to conveniently integrate the images as documentation in the forensic reports as a supplement for the forensic odontologist in the identification process.
Purpose: To demonstrate the workflow used in the evaluation of Post Mortem MSCT as part of dental identification in single and possibly multiple fatalities. Material and method: The workflow in a couple of cases from the Section of
Forensic Pathology in Copenhagen, Denmark is used to illustrate how the use of OsiriX® DICOM Viewer and its tools can be applied to overcome some of the problems contained in MSCT images compared to the usual
ortopantomograms used in forensic odontology for identification. Results, discussion and conclusion: The combined use of tomograms (slices), 2D Mean Intensity Projection and 3D MIP/VR (3D Maximum Intensity Projection/Volume
Rendering) was found to give a very useful first view for the forensic odontological evaluation, and the combined use overcomes many of the problems which are contained in the Post Mortem MSCT procedure compared to regular
X-ray examination technique. It is also possible to conveniently integrate the images as documentation in the forensic reports as a supplement for the forensic odontologist in the identification process.
Bidragets oversatte titel | Tandidentifikation ved brug af post mortem CT-skanning: en ny tilgang med brug af OsiriX® |
---|---|
Originalsprog | Engelsk |
Publikationsdato | 20 aug. 2012 |
Antal sider | 1 |
Status | Udgivet - 20 aug. 2012 |
Begivenhed | EAFS 2012: Forensic Science 2.0 - The Hague University of Applied Sciences, Haag, Holland Varighed: 20 aug. 2012 → 24 aug. 2012 Konferencens nummer: 6th European Academy of Forensic Science Conference |
Konference
Konference | EAFS 2012 |
---|---|
Nummer | 6th European Academy of Forensic Science Conference |
Lokation | The Hague University of Applied Sciences |
Land/Område | Holland |
By | Haag |
Periode | 20/08/2012 → 24/08/2012 |
Emneord
- Det Sundhedsvidenskabelige Fakultet
- Retsmedicin
- Retsodontologi
- Post Mortem MSCT
- Identifikation
- CT