TY - JOUR
T1 - Comparison of CO2, CH4 and N2O soil-atmosphere exchange measured in static chambers with cavity ring-down spectroscopy and gas chromatography
AU - Christiansen, Jesper Riis
AU - Outhwaite, Josh
AU - Smukler, Sean M.
PY - 2015/10/5
Y1 - 2015/10/5
N2 - A laboratory and field experiment compared fluxes of CO2, CH4 and N2O measured with cavity ring-down spectroscopy (CRDS) and gas chromatography (GC). The comparison between CRDS and GC showed that average CO2 fluxes were significantly higher for CRDS in both the laboratory and field, but the same experimental treatments effects were detected for both techniques. Compared to CRDS, the GC technique was severely limited in detecting CH4 fluxes in both the laboratory and field. Thus, only 16% of measured GC fluxes were detectable in the laboratory and none in the field whereas CRDS could detect 65% and 97% of the CH4 fluxes in the laboratory and field. In contrast, N2O fluxes measured with CRDS and GC were not different for both the laboratory and field. It was observed that a lower proportion of N2O fluxes could be detected with CRDS (73%) than GC (92%) in the laboratory and similar recovery (65% and 68%) for the field. Thus, the same treatment effects were observed for both CRDS and GC. Furthermore, the comparison between CRDS and GC showed that enclosure times as short as 600s for our field study site are suitable to estimate the same treatment effects, but not necessarily flux magnitude. We conclude that CRDS and GC can provide the same level of information regarding treatment effects in both laboratory and field experiments for CO2 and N2O, but not for CH4 and it is possible to reduce enclosure time without comprising comparability between the two techniques.
AB - A laboratory and field experiment compared fluxes of CO2, CH4 and N2O measured with cavity ring-down spectroscopy (CRDS) and gas chromatography (GC). The comparison between CRDS and GC showed that average CO2 fluxes were significantly higher for CRDS in both the laboratory and field, but the same experimental treatments effects were detected for both techniques. Compared to CRDS, the GC technique was severely limited in detecting CH4 fluxes in both the laboratory and field. Thus, only 16% of measured GC fluxes were detectable in the laboratory and none in the field whereas CRDS could detect 65% and 97% of the CH4 fluxes in the laboratory and field. In contrast, N2O fluxes measured with CRDS and GC were not different for both the laboratory and field. It was observed that a lower proportion of N2O fluxes could be detected with CRDS (73%) than GC (92%) in the laboratory and similar recovery (65% and 68%) for the field. Thus, the same treatment effects were observed for both CRDS and GC. Furthermore, the comparison between CRDS and GC showed that enclosure times as short as 600s for our field study site are suitable to estimate the same treatment effects, but not necessarily flux magnitude. We conclude that CRDS and GC can provide the same level of information regarding treatment effects in both laboratory and field experiments for CO2 and N2O, but not for CH4 and it is possible to reduce enclosure time without comprising comparability between the two techniques.
KW - cavity ring-down spectroscopy
U2 - 10.1016/j.agrformet.2015.06.004
DO - 10.1016/j.agrformet.2015.06.004
M3 - Tidsskriftartikel
SN - 0168-1923
VL - 211-212
SP - 48
EP - 57
JO - Agricultural and Forest Meteorology
JF - Agricultural and Forest Meteorology
ER -