T1 - Clinical assessment of hip strength using a hand-held dynamometer is reliable
AU - Thorborg, K
AU - Petersen, J
AU - Magnusson, S P
AU - Hölmich, P
PY - 2010/6/1
Y1 - 2010/6/1
N2 - Hip strength assessment plays an important role in the clinical examination of the hip and groin region. The primary aim of this study was to examine the absolute test-retest measurement variation concerning standardized strength assessments of hip abduction (ABD), adduction (ADD), external rotation (ER), internal rotation (IR), flexion (FLEX) and extension (EXT) using a hand-held dynamometer. Nine subjects (five males, four females), physically active for at least 2.5 h a week, were included. Twelve standardized isometric strength tests were performed twice with a 1-week interval in between by the same examiner. The test order was randomized to avoid systematic bias. Measurement variation between sessions was 3-12%. When the maximum value of four measurements was used, test-retest measurement variation was below 10% in 11 of the 12 individual hip strength tests and below 5% in five of the 12 tests. No systematic differences were present. Standardized strength assessment procedures of hip ABD, ER, IR, FLEX, with test-retest measurement variation below 5%, hip ADD below 6% and hip EXT below 8%, make it possible to determine even small changes in hip strength at the individual level.
AB - Hip strength assessment plays an important role in the clinical examination of the hip and groin region. The primary aim of this study was to examine the absolute test-retest measurement variation concerning standardized strength assessments of hip abduction (ABD), adduction (ADD), external rotation (ER), internal rotation (IR), flexion (FLEX) and extension (EXT) using a hand-held dynamometer. Nine subjects (five males, four females), physically active for at least 2.5 h a week, were included. Twelve standardized isometric strength tests were performed twice with a 1-week interval in between by the same examiner. The test order was randomized to avoid systematic bias. Measurement variation between sessions was 3-12%. When the maximum value of four measurements was used, test-retest measurement variation was below 10% in 11 of the 12 individual hip strength tests and below 5% in five of the 12 tests. No systematic differences were present. Standardized strength assessment procedures of hip ABD, ER, IR, FLEX, with test-retest measurement variation below 5%, hip ADD below 6% and hip EXT below 8%, make it possible to determine even small changes in hip strength at the individual level.
U2 - 10.1111/j.1600-0838.2009.00958.x
DO - 10.1111/j.1600-0838.2009.00958.x
M3 - Journal article
SN - 0905-7188
VL - 20
SP - 493
EP - 501
JO - Scandinavian Journal of Medicine & Science in Sports
JF - Scandinavian Journal of Medicine & Science in Sports
IS - 3
ER -