Cerebrospinal fluid clearance in Alzheimer disease measured with dynamic PET

Mony J. De Leon*, Yi Li, Nobuyuki Okamura, Wai H. Tsui, Les A. Saint-Louis, Lidia Glodzik, Ricardo S. Osorio, Juan Fortea, Tracy Butler, Elizabeth Pirraglia, Silvia Fossati, Hee Jin Kim, Roxana O. Carare, Maiken Nedergaard, Helene Benveniste, Henry Rusinek

*Corresponding author af dette arbejde
    53 Citationer (Scopus)

    Abstract

    Evidence supporting the hypothesis that reduced cerebrospinal fluid (CSF) clearance is involved in the pathophysiology of Alzheimer disease (AD) comes primarily from rodent models. However, unlike rodents, in which predominant extracranial CSF egress is via olfactory nerves traversing the cribriform plate, human CSF clearance pathways are not well characterized. Dynamic PET with 18F-THK5117, a tracer for tau pathology, was used to estimate the ventricular CSF time-activity as a biomarker for CSF clearance. We tested 3 hypotheses: extracranial CSF is detected at the superior turbinates; CSF clearance is reduced in AD; and CSF clearance is inversely associated with amyloid deposition. Methods: Fifteen subjects, 8 with AD and 7 normal control volunteers, were examined with 18F-THK5117. Ten subjects additionally underwent 11C-Pittsburgh compound B (11C-PiB) PET scanning, and 8 were 11C-PiB-positive. Ventricular time-activity curves of 18F-THK5117 were used to identify highly correlated time-activity curves from extracranial voxels. Results: For all subjects, the greatest density of CSF-positive extracranial voxels was in the nasal turbinates. Tracer concentration analyses validated the superior nasal turbinate CSF signal intensity. AD patients showed ventricular tracer clearance reduced by 23% and 66% fewer superior turbinate CSF egress sites. Ventricular CSF clearance was inversely associated with amyloid deposition. Conclusion: The human nasal turbinate is part of the CSF clearance system. Lateral ventricle and superior nasal turbinate CSF clearance abnormalities are found in AD. Ventricular CSF clearance reductions are associated with increased brain amyloid depositions. These data suggest that PET-measured CSF clearance is a biomarker of potential interest in AD and other neurodegenerative diseases.

    OriginalsprogEngelsk
    TidsskriftJournal of Nuclear Medicine
    Vol/bind58
    Udgave nummer9
    Sider (fra-til)1471-1476
    Antal sider6
    ISSN0161-5505
    DOI
    StatusUdgivet - 2017

    Fingeraftryk

    Dyk ned i forskningsemnerne om 'Cerebrospinal fluid clearance in Alzheimer disease measured with dynamic PET'. Sammen danner de et unikt fingeraftryk.

    Citationsformater