T1 - Bone marrow oedema assessment by magnetic resonance imaging in rheumatoid arthritis wrist and metacarpophalangeal joints
T2 - the importance of field strength, coil type and image resolution
AU - Krabbe, Simon
AU - Eshed, Iris
AU - Pedersen, Susanne Juhl
AU - Bøyesen, Pernille
AU - Møller, Jakob M
AU - Therkildsen, Flemming
AU - Axelsen, Mette Bjørndal
AU - Madsen, Ole Rintek
AU - Østergaard, Mikkel
N1 - © The Author 2014. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: [email protected].
PY - 2014/8
Y1 - 2014/8
N2 - OBJECTIVE: The aim of this study was to examine the influence of different MRI unit field strengths, coil types and image resolutions on the OMERACT RA MRI scoring system (RAMRIS) of bone marrow oedema (BME) and image quality.METHODS: Forty-one patients and 12 healthy controls participated in this cross-sectional study. Coronal short tau inversion recovery (STIR) and T1-weighted sequences were obtained at 0.23, 0.6, 1.5 and 3T using flex coils (Flex). Additional STIR sequences were obtained with phased array extremity coils (Extr) (at 0.6 and 1.5T) and higher resolution (at 1.5T). In otal, 338 STIR image sets were anonymized and scored according to RAMRIS and parameters of image quality were measured.RESULTS: The BME sum scores were similar overall when comparing the different MRI units, coil types and voxel sizes, yet significantly higher at the higher resolution of 1.5T Extr compared with 0.23T Flex (P = 0.004), 0.6T Flex (P = 0.03), 1.5T Flex (P = 0.05) and 3T Flex (P = 0.001). Mean differences were relatively minor (0-3.5). Intrareader reliability of BME scores was high [intraclass correlation coefficient ≥ 0.90 for all except 0.23T (0.81) and percentage exact agreement 81-88%]. The smallest detectable difference was better at 0.6, 1.5 and 3T (9-29% of maximum value) than at 0.23T (40%). Image quality was lowest at 0.23T.CONCLUSION: No major, consistent differences were found between BME scores using STIR sequences obtained at different field strengths, coil types and image resolutions, suggesting that these are equally suited for assessment of BME in RA. However, parameters of image quality and intrareader reliability (favouring 0.6, 1.5 and 3T) should be considered when selecting the MRI acquisition strategy.
AB - OBJECTIVE: The aim of this study was to examine the influence of different MRI unit field strengths, coil types and image resolutions on the OMERACT RA MRI scoring system (RAMRIS) of bone marrow oedema (BME) and image quality.METHODS: Forty-one patients and 12 healthy controls participated in this cross-sectional study. Coronal short tau inversion recovery (STIR) and T1-weighted sequences were obtained at 0.23, 0.6, 1.5 and 3T using flex coils (Flex). Additional STIR sequences were obtained with phased array extremity coils (Extr) (at 0.6 and 1.5T) and higher resolution (at 1.5T). In otal, 338 STIR image sets were anonymized and scored according to RAMRIS and parameters of image quality were measured.RESULTS: The BME sum scores were similar overall when comparing the different MRI units, coil types and voxel sizes, yet significantly higher at the higher resolution of 1.5T Extr compared with 0.23T Flex (P = 0.004), 0.6T Flex (P = 0.03), 1.5T Flex (P = 0.05) and 3T Flex (P = 0.001). Mean differences were relatively minor (0-3.5). Intrareader reliability of BME scores was high [intraclass correlation coefficient ≥ 0.90 for all except 0.23T (0.81) and percentage exact agreement 81-88%]. The smallest detectable difference was better at 0.6, 1.5 and 3T (9-29% of maximum value) than at 0.23T (40%). Image quality was lowest at 0.23T.CONCLUSION: No major, consistent differences were found between BME scores using STIR sequences obtained at different field strengths, coil types and image resolutions, suggesting that these are equally suited for assessment of BME in RA. However, parameters of image quality and intrareader reliability (favouring 0.6, 1.5 and 3T) should be considered when selecting the MRI acquisition strategy.
KW - Aged
KW - Arthritis, Rheumatoid
KW - Bone Marrow
KW - Bone Marrow Diseases
KW - Cross-Sectional Studies
KW - Edema
KW - Female
KW - Humans
KW - Magnetic Resonance Imaging
KW - Male
KW - Metacarpophalangeal Joint
KW - Middle Aged
KW - Reproducibility of Results
KW - Wrist Joint
U2 - 10.1093/rheumatology/keu029
DO - 10.1093/rheumatology/keu029
M3 - Journal article
C2 - 24659753
SN - 1462-0324
VL - 53
SP - 1446
EP - 1451
JO - Rheumatology (Oxford, England)
JF - Rheumatology (Oxford, England)
IS - 8
ER -