Abstract
Compound refractive lenses (CRL) are widely used to manipulate synchrotron radiation beams. Accurate modelling of X-ray beam propagation through individual lenses and through "transfocators"composed of a large number of CRLs is of high importance, since it allows for comprehensive optimization of X-ray beamline designs for particular user experiments. In this work we used the newly developed McXtrace ray-tracing package and the SRW wave-optics code to simulate the beam propagation of X-ray undulator radiation through such a "transfocator"as implemented at ID-11 at ESRF. By applying two complementary simulation methods, we were able to obtain comparable results (e.g. the beam's focused properties) and also to provide a complete description of X-ray beam propagation through the CRLs and other optical components. However, some discrepancies between the results acquired by both methods (e.g. broader monochromatization degree obtained with the McXtrace code) brought a meaningful insight into further development strategies for the McXtrace package.
Originalsprog | Engelsk |
---|---|
Tidsskrift | Proceedings of SPIE |
Vol/bind | 8141 |
Sider (fra-til) | 814111 |
ISSN | 0277-768X |
DOI | |
Status | Udgivet - 23 sep. 2011 |