AC Losses in Bi(2)Sr(2)Ca(2)Cu(3)O(10+x) Tapes and a 3.15-m-Long Single-Phase Cable

Jeppe Søgaard Juul, Esben Tore Molgaard, Jens Jensen, Niels Hessel Andersen, Asger Bech Abrahamsen, C. Traeholt...[et al.]

1 Citationer (Scopus)

Abstract

The alternating-current losses in superconducting multifilament BiSCCO-2223 tapes and a 3.15-m single-phase test cable were measured at 77 K using an electrical transport method. The cable had an inner diameter of 42 mm; it was composed of a single layer of 31 multifilament tapes and had a critical current of Ic = 4.1kA. The measured losses of the tapes were found to be in good agreement with the Norris ellipse (NE) model. The losses of the cable were, for high currents, found to be bounded by the monoblock and independent NE models.

OriginalsprogEngelsk
TidsskriftIEEE Transactions on Applied Superconductivity
Vol/bind21
Udgave nummer6
Sider (fra-til)3599-3603
ISSN1051-8223
DOI
StatusUdgivet - 1 dec. 2011

Fingeraftryk

Dyk ned i forskningsemnerne om 'AC Losses in Bi(2)Sr(2)Ca(2)Cu(3)O(10+x) Tapes and a 3.15-m-Long Single-Phase Cable'. Sammen danner de et unikt fingeraftryk.