TY - JOUR
T1 - A 2-year report on maxillary and mandibular fixed partial dentures supported by Astra Tech dental implants. A comparison of 2 implants with different surface textures
AU - Karlsson, U
AU - Gotfredsen, K
AU - Olsson, C
N1 - Keywords: Alveolar Bone Loss; Dental Implantation, Endosseous; Dental Implants; Dental Polishing; Dental Prosthesis Design; Dental Prosthesis, Implant-Supported; Dental Restoration Failure; Denture, Partial, Fixed; Female; Humans; Jaw, Edentulous, Partially; Male; Middle Aged; Prospective Studies; Surface Properties
PY - 1998
Y1 - 1998
N2 - In 50 partially edentulous patients, 133 (48 maxillary; 85 mandibular) Astra Tech dental implants of 2 different surface textures (machined; TiO-blasted) were alternately installed, supporting 52 fixed partial dentures (FPDs). Before abutment connection 2 machined implants (1 mandibular; 1 maxillary) were found to be non-osseointegrated and were replaced. Another implant could not be restored due to a technical complication. Two FPDs were remade because of technical complications, both because of abutment fractures. Thus, after 2 years in function, the cumulative survival rates were 97.7% and 95.7% for implants and prostheses, respectively. There was no statistically significant difference in survival rate between the 2 types of implants, 100% (TiO-blasted) vs 95.3% (machined), P = 0.24. After 2 years in function, when both jaw and type of implants were combined, the mean (SD) marginal bone loss was 0.24 (0.69) mm. No statistically significant difference in bone loss was found between the 2 types of implant after 2 years of loading, 0.04 (0.82) mm, P > 0.30.
AB - In 50 partially edentulous patients, 133 (48 maxillary; 85 mandibular) Astra Tech dental implants of 2 different surface textures (machined; TiO-blasted) were alternately installed, supporting 52 fixed partial dentures (FPDs). Before abutment connection 2 machined implants (1 mandibular; 1 maxillary) were found to be non-osseointegrated and were replaced. Another implant could not be restored due to a technical complication. Two FPDs were remade because of technical complications, both because of abutment fractures. Thus, after 2 years in function, the cumulative survival rates were 97.7% and 95.7% for implants and prostheses, respectively. There was no statistically significant difference in survival rate between the 2 types of implants, 100% (TiO-blasted) vs 95.3% (machined), P = 0.24. After 2 years in function, when both jaw and type of implants were combined, the mean (SD) marginal bone loss was 0.24 (0.69) mm. No statistically significant difference in bone loss was found between the 2 types of implant after 2 years of loading, 0.04 (0.82) mm, P > 0.30.
M3 - Journal article
C2 - 9760898
SN - 0905-7161
VL - 9
SP - 235
EP - 242
JO - Clinical Oral Implants Research
JF - Clinical Oral Implants Research
IS - 4
ER -