Should dosing of rocuronium in obese patients be based on ideal or corrected body weight?

Christian S Meyhoff, Jørgen Lund, Morten T Jenstrup, Casper Claudius, Anne M Sørensen, Jørgen Viby-Mogensen, Lars S Rasmussen

    72 Citations (Scopus)

    Abstract

    BACKGROUND: Pharmacokinetic studies in obese patients suggest that dosing of rocuronium should be based on ideal body weight (IBW). This may, however, result in a prolonged onset time or compromised conditions for tracheal intubation. In this study, we compared onset time, conditions for tracheal intubation, and duration of action in obese patients when the intubation dose of rocuronium was based on three different weight corrections. METHODS: Fifty-one obese patients, with a median (range) body mass index of 44 (34-72) kg/m2, scheduled for laparoscopic gastric banding or gastric bypass under propofol-remifentanil anesthesia were randomized into three groups. The patients received rocuronium (0.6 mg/kg) based on IBW (IBW group, n = 17), IBW plus 20% of excess weight (corrected body weight [CBW]20% group, n = 17), or IBW plus 40% of excess weight (CBW40% group, n = 17). Propofol was administered as a bolus of 200 mg and an infusion at 5 mg x kg(-1) x h(-1) and remifentanil was administered at 1.0 microg x kg(-1) x min(-1), both according to CBW40%. Neuromuscular function was monitored with train-of-four nerve stimulation and acceleromyography. The primary end point was duration of action, defined as time to reappearance of the fourth twitch in train-of-four. RESULTS: The median (range) duration of action was 32 (18-49), 38 (25-66), and 42 (24-66) min in the IBW, CBW20%, and CBW40% groups, respectively (P = 0.001 for comparison of the IBW and CBW40% group). There were no significant differences in onset time (85 vs 84 vs 80 s) or in intubation conditions 90 s after administration of rocuronium. CONCLUSIONS: In obese patients undergoing gastric banding or gastric bypass, rocuronium dosed according to IBW provided a shorter duration of action without a significantly prolonged onset time or compromised conditions for tracheal intubation.
    Original languageEnglish
    JournalAnesthesia and Analgesia
    Volume109
    Issue number3
    Pages (from-to)787-92
    Number of pages5
    ISSN0003-2999
    DOIs
    Publication statusPublished - 2009

    Fingerprint

    Dive into the research topics of 'Should dosing of rocuronium in obese patients be based on ideal or corrected body weight?'. Together they form a unique fingerprint.

    Cite this