Required time delay from 99mTc-HMPAO injection to SPECT data acquisition: healthy subjects and patients with rCBF pattern

Gerda Thomsen, Robin de Nijs, Esben Hogh-Rasmussen, Vibe Frokjaer, Claus Svarer, Gitte M Knudsen

8 Citationer (Scopus)

Abstract

Functional brain (99m)Tc-HMPAO single-photon emission computed tomography (SPECT) is a useful diagnostic tool for assessment of regional cerebral blood flow, particularly in dementia, cerebrovascular disease and epilepsy. Currently, the European and American Association of Nuclear Medicine Procedure Guidelines for Brain Perfusion SPET using (99m)Tc-labeled Radiopharmaceuticals recommend a time delay of 90 min between injection of (99m)Tc-HMPAO and data acquisition. This time delay is difficult to comply within the daily routine and present a problem, particularly with the elderly or demented patients. This study investigates in patients with perfusion deficits and in healthy subjects if the quality of the SPECT image is affected by lowering the time delay between (99m)Tc-HMPAO injection and data acquisition to 30 or 60 min.
OriginalsprogEngelsk
TidsskriftEuropean Journal of Nuclear Medicine and Molecular Imaging
Vol/bind35
Udgave nummer12
Sider (fra-til)2212-9
Antal sider8
ISSN1619-7070
DOI
StatusUdgivet - 1 dec. 2008

Fingeraftryk

Dyk ned i forskningsemnerne om 'Required time delay from 99mTc-HMPAO injection to SPECT data acquisition: healthy subjects and patients with rCBF pattern'. Sammen danner de et unikt fingeraftryk.

Citationsformater